< Terug naar vorige pagina

Publicatie

A highly efficient and energy-saving magnetically induced membrane vibration system for harvesting microalgae

Tijdschriftbijdrage - Tijdschriftartikel

The optimal operational parameters of a second generation magnetically induced membrane vibration (MMV) system were determined using the response surface methodology (RSM) combined with single-factor experiments. The membrane surfaces were characterized by scanning electron microscopy (SEM) and algae cell states by inverted microscopy. The effect of an intermittent vibration strategy on filtration performance and energy consumption was studied. The results showed that the responses could be fitted by RSM models. High membrane flux, low energy consumption, efficient fouling control and no damage to the microalgae could thus be realized. The filtration strategy tests suggested that an intermittent cycle time of 4 min with 50% vibration rate could be the best vibration strategy for harvesting the microalgae under investigation.
Tijdschrift: Bioresource Technology
ISSN: 0960-8524
Volume: 300
Jaar van publicatie:2020
BOF-keylabel:ja
IOF-keylabel:ja
BOF-publication weight:10
CSS-citation score:3
Authors from:Higher Education
Toegankelijkheid:Closed